IAQ Applications : VOC Monitoring
Ruks ControZone CZ1 offers
reliable, efficient and cost effective solution to track and control VOC in your indoor environment. Duct,
plenum or space mounting options offer total flexibility to suit all applications. A watch dog of your air
quality, it continuously tracks weighted average of concentration of prevailing VOC. Through Variable Load
Controller, provides variable voltage to modulate IAQ devices, to eliminate or minimize offending VOC,
odor and smoke. With suitably sized Ruks Ozone Generators, helps reduce HVAC plant size and operating cost. Your silent partner in improving IAQ, ControZone CZ1 helps reduce HVAC capital and operating costs.
MODE OF OPERATION:
Sensor module is remote mounted and
provides rapid response to changes in
VOC. Based on the level of VOC sensed,
CZ1 provides variable signals to Load
Controller. Sensor module provides user
selectable 0 to 10 VDC single analog
stepped or 0 to 5 VDC proportional output,
for interface to Automated Building
Management System. Solid state Variable
Load Controller accepts input from Sensor
module and converts applied line voltage
to variable output voltage, used to
modulate air quality devices. Single power
source to Sensor and Controller.
Potentiometers for 1 level of clean room
and 3 Levels of pollution, each individually
field adjustable. Baseline of the sensor is
factory set to clean air conditions.
Sensitivity pot on the sensor provides users
the option to set baseline to customize
their requirement. Preset sensitivity of the
sensor is retained in the event power is
lost, or if the system is turned off for
maintenance. May be used in fully
automatic or manual mode.
Ruks ControZone CZ1 is fully factory
assembled with interconnecting cables
between Sensor and Controller modules.
The only field provided requirement is
power wiring, and is ready to start.
SUGGESTED APPLICATIONS
- Ozone Generators
- Outdoor Air or Exhaust Air Dampers
- Outdoor Air or Exhaust Air Fans
- Balancing Dampers
- Visual LED indications for Clean Room,
and 3 level of VOC in Indoor Space,
Duct, Plenum or Process Chamber
- Interface to Automated Building
Management System
PRODUCT SPECIFICATIONS OF RUKS CONTROZONE CZ1
SENSOR
Sensor Size: 4"W x 6"H (102 x 152)
Aspiration Box Size: 6.5"W x 7.5"H x 4"D
(165 x 191x102)
Aspiration Box Weight: 3 Lbs (1.36 Kg)
Aspiration Box Material: Stainless Steel
Output: 4 Channels: Clean, Low, Medium,
High
Gases Detected: Total VOC in Air Stream
Rating: Continuous Operation
5 LED Lamps: Warm Up, Clean Room, Low,
Medium, High
Calibration Gas: Isobutylene 100 PPM
Warm Up Time: 3 Minutes
Mounting: Duct, Plenum, Chamber, or
Space
Operating Humidity Range: 45% to 65%
Sensor Life: 5 Years (subject to proper use
and care)
Output to Automated Building
Management System: 0 to 10 VDC stepped
and 0 to 5 VDC proportional, user
selectable.
CONTROLLER
Size: 10"W x 11"H x 3"D (254x279x76)
Weight: 5 Lbs (2.27 Kg)
Input: 120 Volts, 1 Ph, 60 Hz Or 220 Volts,
1 Ph, 50 Hz
Case Material: Stainless Steel
Output: 1 Variable Output
Adjustable From 0 to 100% at Sensor box
Rating: Continuous Operation
Terminals: 3 for Incoming power,
3 for variable Outgoing power to IAQ
device, and 2 for Interlock
3 LED Lamps: Power On, Auto, Manual.
RECOMMENDED PROJECT SPECIFICATIONS:
SENSOR MODULE
- Regulation of IAQ device shall be automatically
controlled by Ruks ControZone CZ1 system,
comprising Auto VOC Sensor and Variable Load
Controller.
- Sensor and Controller shall be rated for continuous
operation.
- Sensor shall be suitable for mounting in space, duct,
plenum, or process chamber. If not space mounted,
it shall be provided with Stainless Steel Air
Aspiration enclosure. Sampling air shall be aspirated
to the enclosure and released.
- The Sensor shall be factory calibrated to Isobutylene
gas 100 PPM for full span and controlled clean air
for zero span. Factory stamped calibration
certificate with date of calibration shall be provided
with each Sensor.
- The VOC Sensor shall be capable of detecting broad
range of commonly occurring VOC in indoor
applications. Each gas sensed is related by the
sensor to its corresponding concentration value to
isobutylene.
- The Sensor shall provide 4 distinct signals, one each
for Clean, Low, Medium and High levels of
concentration of the polluting VOC. The Sensor shall
have 5 LED displays to provide visual indications for
the 4 levels, and warm up phase. It shall be possible
to field adjust the sensitivity of the sensor.
- The sensor shall provide 0 to 10 VDC stepped and
0 to 5 VDC proportional output, field selectable, for
interface to Automated Building Management
System.
- In the event of power failure, or if the system is
turned off, the Sensor shall retain the pre set
sensitivity.
- The sensor shall be provided with potentiometers to
adjust the 4 levels of pollution, independent of one
another.
- The Sensor shall be suitable for operation in air
stream of RH 45% to 65%.
- Factory supplied interconnecting cable shall be
provided, for communication between Sensor and
Load Controller.
VARIABLE LOAD CONTROLLER
- Controller shall be solid state, mounted in rugged
stainless steel enclosure.
- It shall be fully factory assembled. Field provided
connections shall be limited to power wiring.
- The Controller shall be suitable for accepting signals
from the Sensor. Based on the signals received, it
shall provide variable output to operate IAQ devices.
- Input voltage to controller shall be 120 Volts,
1 Ph, 60 Hz or 220 to 240 Volts, 1 Ph, 50 Hz
(Factory set). It shall be suitable for load rating of
10 Amps.
- Controller shall be provided with terminal block to
connect incoming power, variable outgoing power,
and for interlock to AHU motor or other air moving
device, and to safety device such as high ozone cut
out switch.
- The Controller shall be provided with receptacle to
accept easy plug in cable connector, for
communication to Sensor.
- Controller shall provided with 3 Lamps to indicate
Power On, Automatic, Manual Bypass.
- Controller shall be provided with rocker switch to
choose Automatic or Manual Mode of operation. In
the Manual Bypass Mode, voltage output of the
Controller shall be 100% of input voltage, regardless
of the level of VOC.
- Cable connector between Controller and Sensor,
length not less than 25 ft (7.5 M) shall be factory
provided (specify length if longer than 25 feet is
required). This shall be complete with cables to
provide power to Sensor and transfer signals for the
different levels of VOC from Sensor to Controller.
- The Sensor Controller shall be Ruks ControZone
Model CZ1. Country of manufacture shall be USA.
|
|
|