Benefits of Controlled Ozone Injection System
RUKS ENGINEERED SYSTEMS ACHIEVE
- Reduction of VOC and gaseous Organic pollutants
- Near total elimination of organic odor
- Near total elimination of smoke due to cooking and cigarettes
- Dramatic reduction of fungi in HVAC coil, duct and drain pan
- Clean Ducts and AHU sections by eliminating bio adhesive force needed for particulate adherence to surface
- Near Total elimination of Air Borne Bacteria in AC ducts, Cooling Coils and drain pan
- Residual ozone level in Indoor space well below ASHRAE, OSHA, ACGIH, EPA and WHO permissible level
- Regulation of outdoor air damper to maintain CO2 level to ASHRAE and OSHA standards
- Reduction in HVAC plant capacity. Saves on capital cost of HVAC Systems, often sufficient to offset investment on ozone systems and associated controls and monitors
- Reduction in operating cost of HVAC system by reducing energy and water. In most applications, savings in operating cost over 1 to 2 years offset total investment on ozone system and associated controls and monitors. Life cycle cost saving is enormous
- System is fully automatic, with VOC Monitor, Ozone Monitor, CO2 Monitor, and Controllers
- Provides 4 to 20 mA or 0 to 10 VDC for total integration to computerized Building Management Systems
- Provides output to computer. May be used to provide time history records, records of residual VOC, Ozone, and CO2, retain hard copy records and management information reports o Modern, state of the art IAQ Monitors
Ruks Engineering is committed to keep your indoor space a clean environment.
QUALITY, COMFORT AND ECONOMY FEATURES
- Automatic continuous modulation of ;
- Ozone Generators and Demand Load Ventilation, based on residual VOC level
- Automatic cut out of Ozone Generators, with or without alarm, if residual ozone concentration exceeds set value
- Outdoor air damper, based on CO2 level
- Two or three way mixing or diverting valve for cooling or heating coil, based on Temperature
- Two way valve to control humidifier
- NO (Normally Open) Dry Contact to activate On Off devices to control VOC, CO2, O3, Temperature and RH.
- Digital read out of VOC, CO2, O3, Temperature and RH, in user selectable units, at all times
- User selectable alarm for VOC, CO2, O3, Temperature and RH
- Real Time and Time History records of VOC, CO2, O3, Temperature, and RH, exceedance and alarm reports, options to record variation of outdoor air flow, at all times
- BacNet, Modbus and 0-10 VDC interface to BAS (BMS) for all parameters and generate Management Reports
- No chemicals used. Environmentally friendly
BENEFITS
- Clean Indoor Environment with significantly reduced VOC, toxic gases, smoke, and odor
- Near total elimination of Mold and Fungi
- Near total elimination of dust and particulates in AC ducts and Cooling Coil
- Near total elimination of Air Borne Bacteria in AC ducts
- Clean HVAC ducts, air coil, and AHU sections
- Residual CO2 within ASHRAE and OSHA standards
- Reduction in Capital Cost of HVAC System
- Significant reduction in energy and water cost to operate HVAC System